| Main configuration | External Inductors | Internal Integrated Inductors |
| Heating Configuration | Heating with mold closed / airgap needed | Possible to heat with opened mold |
| Max. temperature | 400°C or more | 400°C or more |
| Simulation stude (FEA) | YES | YES |
| 1 side heating | NO | YES |
| 2 side heating | YES | YES |
| Power input | From 5kw to 500kw | From 5kw to 500kw |
| Depending on part dimensions and cycle time requirements Small (200x200) 10 to 50kw | Medium (500x500) 50 to 200kw | Large (1m x 1m or larger) 100 to 500kw |
| Mold requirements | Magnetic steel | Magnetic steel |
| Cooling type | Water (turbulent flow) | Water (turbulent flow) |
| Heat and Cool performance | 10°C/sec heating or more | 10°C/sec heating or more |
| 8°C/sec cooling or more | 8°C/sec cooling or more |
| Constant temp control | Yes, sensors and regulators | Yes, sensors and regulators |